Noble Metal Thermocouples are manufactured with precious or noble metals like Platinum and Rhodium. Noble metal thermocouples can be used in oxidizing or inert applications and must be used with a ceramic protection tube surrounding the thermocouple element. These are normally used for high-temperature applications. These sensors are usually fragile and must not be used in applications that are reducing or in applications that contain metallic vapors.
Type | R,S,B |
Element Dlaimeter | 0.30,0.35,0.4,0.45,0.5 mm other sizes on request |
Sheath Material | Recrystallized Alumina Ceramic(C-799), 610,Inconel, Silicon Carbide, Platinum etc |
Configuiratlon | Simplex/ DuplexiMultipoint |
Special | Hot Blast & stove Dome Thermocouples,Tri-Level Thermocouples, Crown Thermocouples |
Type | Names of Materials | Application Range | Application |
R | PIatinum 13% Rhodium(+) PIatinum (-) | 0 to 1450℃ | lnert Media,Oxidizing media |
S | Platinum 10% Rhodium(+) PIatinum (-) | 0 to 1450℃ | lnert Media,Oxidizing media |
B | PlaHnum 30% Rhodlum(+) PIatinum 6% Rhodlum (-) | 800 to 1700℃ | lnert Media,Oxidizing media |
PyroTech Instrument Pty Ltd
Head Office:
Address: 7 Yamma Street Sefton NSW 2164, Sydney Australia.
Phone:
61 2 9721 8668
Fax: 61 2 9738 9343
email:
sales@pyrotech.com
Website:
www.pyro-technology.com
China Office
Address: Room 401, Building 9, Jinbin Ruicheng, Jinbin Industrial Park, Wuqing District, Tianjin
Phone: ++86 15320153058
Fax: ++86 022-88984836
Email:
pyrotechcn@163.com
Website: www.pyro-technology.com
客户留言
Description: