PPT-G Series

PPT-G Series monosilicon pressure transmitter is a highperformance pressure transmitter with internationalleading technology meticulously designed by Pyrotechinstrument company,using the world's most advancedmonosilicon pressure sensor technology and
Number of views:
846
Product serial number
Quantity
-
+
Product description

lndustrial gauge pressure transmitter

PPT-G Series monosilicon pressure transmitter is a highperformance pressure transmitter with internationalleading technology meticulously designed by Pyrotech instrument company,using the world's most advancedmonosilicon pressure sensor technology and patentencapsulation technology. Monosilicon pressure sensorlocates on the top of the metal body and stay away fromthe medium interface to realizes mechanical isolation andthermal isolation. Glass sintering sensor wire realizes highstrength electrical insulation of metal base and improvesthe capability of flexibility of electronic circuit and transientvoltage resistance protection. All these original encapsula--tion technologies enable PPTS to easily cope with extremechemical occasion and mechanical load, and own strongresistance to EMl, sufficient to respond to the rigorousindustrial environment applications, which are the genuineinvisible instruments.

Main parameters

Pressure types

Gauge pressure

Measuring range

2kPa-40MPa, please refer to theordering information chapter

Output signal

4-20mA,4-20mA+HART, customer

Reference accuracy

±0.1% URL, optional 0.075%URL

Field of application

Pressure, level

Measuring medium

Liquid, gas, or steam level, density and pressure

Approvals

Measuring range and limit

Nominal value

Smallest calibratable span

Lower range limit(LRL)

Upper range limit(URL)

Overload limit

40kPa

2kPa

-40kPa

40kPa

1MPa

250kPa

12.5kPa

-100kPa

250kPa

4MPa

1MPa

50kPa

-100kPa

1MPa

6MPa

3MPa

150kPa

-0.1kPa

3MPa

15MPa

10MPa

500kPa

-0.1kPa

10MPa

20MPa

40MPa

5kPa

-0.1kPa

40MPa

80MPa

Above measurement range can be replaced by kg/cm², MPa and kPa units .Which can provide other measurement range according to the requirements. Adjust requirements: lower range value (LRV) and upper range value (URV) can be adjusted within the scope of the upper and lower range limit, smallest calibratable span≤|URV-LRV| ≤ upper range limit

Standard specifications and reference conditions

Test standard: GB/T28474 / IEC60770; Zero based- calibration span, Silicon oil filling, 316L stainless steel isolated diaphragm, 4-20mA analog output.

Performance specifications

The overall performance including but not limited to 【reference accuracy 】,【environment temperature
effects】and other comprehensive error

Typical accuracy: ±0.1%URL

Stability: ±0.2% URL/ 5 years

Performance specifications

Standard and reference conditions, including linearity (BFSL), hysteresis and repeatability. calibration temperature: 20 ℃ ± 5 ℃

Linear output accuracy

TD≤10(Note1)

±0.1%URL

Nominal value: 40kPa,250kPa,1MPa,3MPa,10MPa,40MPa

10<TD<20

±0.01% URL

Note 1: TD is Turn down, TD=URL/ |URV-LRV|

Power supply effects

Zero and span change should not be more than ± 0.005% URL/V when power supply changes in 10.5/16.5-55VDC

Mounting position effects

Apply to any position. Max value lower than 400Pa can be corrected by zero clearing function.

Vibration effects

According to GB/T 1827.3/IEC61298-3 tests, <0.1% URL

Output signal

4-20mA two wire. Customers can choose linear output or square root output. Digital process variables superimpose on 4-20mA signal and apply to any hosts with HART protocol.

Ambient temperature effects(Typical)

➣ Within the range -20-80 ℃ total impact

➣ ±(0.1+0.15TD)% URL

Insulation resistance

≥20M Ω@, 100VDC

Damping time

Total damping time constant: equal to the sum of damping time of amplifer and sensor capsule

Damping time of amplifer: 0-100S adjustable

Diaphragm capsule (isolated diaphragm and silicon oil filling)
damping time: ≤0.2s

Startup after power off: ≤6S

Normal services after data recovery: ≤31S

Weight

Net weight: about 1.56kg ( without mounting bracket and process connection adaptor )

Environment condition

Items

Operational condition

Working
temperature

-40-85℃, integrated LCD display : -20-70℃

Storage temperature

-40-110℃, integrated LCD display: - 40-85℃

Media temperature

Silicon oil filling: -40-120℃

Working humidity

5-100% RH@40℃

Protection class

IP66/IP67

Dangerous condition

ExiaIICT4...T6
ExdIICT4...T6

* Only for 4-20mA output

Power supply

Item

Operating conditions

Standard/flame proof

10.5-55VDC

HART protocol

16.5-55VDC, communication load resistance 250Ω

Load resistance

0-2119 Ω for working condition, 250- 600Ω for HART protocol

Transmission distance

<1000m

Power consumption

≤500mW@24VDC, 20.8mA

Power supply and load requirements

EMC environment

NO.

Test items

Basic standards

Test conditions

Performance level

1

Radiated interference

GB/T 9254/CISPR22

30MHz-1000MHz

OK

2

Conducted interference (DC power port)

GB/T 9254/CISPR22

0.15MHz-30MHz

OK

3

Electrostatic discharge immunity test (ESD)

GB/T 17626.2/IEC61000-4-2

4kV(Contact ),8kV(Air)

B(Note2)

4

Immunity to radio frequency EM-fields

GB/T 17626.3/IEC61000-4-3

10V/m(80MHz-1GHz)

A(Note1)

5

Power frequency magnetic field Immunity
test

GB/T 17626.8/IEC61000-4-8

30A/m

A(Note1)

6

Electrical fast transient / Burst Immunity
Test

GB/T 17626.4/IEC61000-4-4

2kV(5/50ns,100kHz)

B(Note2)

7

Surge immunity requirements

GB/T 17626.5/IEC61000-4-5

1kV(Line to line) 2kV(Line to ground)
(1.2us/50us)

B(Note2)

8

Immunity to conducted disturbances
induced by radio frequency fields

GB/T 17626.6/IEC61000-4-6

3V(150kHz-80MHz)

A(Note1)

(Note 1)Performance level A: The preformance within the limits of normal technical specifications.
(Note 2)Performance level B: Temporary reduction or loss of functionality or preformance, it can restore itself. The actual
operating conditions, storage and data will not be changed.

Specific menu

Transmission module type

Output signal

Local control

Remote control

4-20mA+HART

LCD/3 buttons on body

HART

4-20mA

LCD/3 buttons on body

-

LCD display unit

Display mode

Details

PV

Process variable shows on main screen, percentage and progress bar shows on secondary screen

mA

Current shows on main screen, percentage and
progress bar shows on secondary screen

%

Percentage shows on main screen, percentage and progress bar shows on secondary screen

Unit

Unit

Definition

kPa

Kilopascal

MPa

Megapascals

bar

Bar

psi

Pounds per square inch

mmHg

Millimetre(s) of mercury@0℃

mmH2O

Millimeter of water@4℃

mH2O

Meter of water@4℃

inH2O

Inches of water@4℃

ftH2O

Feet of water@4℃

inHg

Inches of mercury@0℃

mHg

Meter mercury column@0℃

TORR

Torr

mbar

Millibar

g/cm²

Gram per square centimeter

kg/cm²

Kilogram per square centimeter

Pa

PA

ATM

Standard atmospheric pressure

mm

Millimeter(Note1)

m

Meter(Note1)

Note1: length unit need mark medium density

Measuring menu set

Mark

State

URV

Upper range value, 20mA

LRV

Lower range value, 4mA

Damping time

Units

Setting range

S

0-100

Analog output type

Parameters

Output type

mA LINER

Linearity

mA√

Square root

Alarm signal

Parameters

Alarm signal

ALARM NO

None

ALARM H

20.8mA

ALARM L

3.8mA

Fix output

Parameters

Fix output value

FIX/C NO

None

3.8000

3.8000mA

4.0000

4.0000mA

8.0000

8.0000mA

12.000

12.000mA

16.000

16.000mA

20.000

20.000mA

20.800

20.800mA

Quick menu

Parameter

Instruction

PV=0

Set current output to zero value, used to correct the error cased by
static pressure and installation.

Zero adjustment

4mA re-range with pressure

Span adjustment

20mA re-range with pressure

Restore factory setting

Restore backup data when error


We could not find any corresponding parameters, please add them to the properties table
Previous
Next

PyroTech Instrument Pty Ltd
Head Office: 

Address: 7 Yamma Street Sefton NSW 2164, Sydney Australia.
Phone: 61 2 9721 8668 
Fax:   61 2 9738 9343
email: sales@pyrotech.com
Website: www.pyro-technology.com

China Office

Address: Room 401, Building 9, Jinbin Ruicheng, Jinbin Industrial Park, Wuqing District, Tianjin
Phone: ++86 15320153058
Fax:   ++86 022-88984836
Email: pyrotechcn@163.com
Website: www.pyro-technology.com

Username used for comment:
客户留言
Description:
验证码

Copyright PyroTech Instrument Pty Ltd. All Rights Reserved