Gauges pressure transmitter

SEARCH PRODUCTS

搜索
Search
All categories

lndustrial gauge pressure transmitter

PPT101 Series monosilicon pressure transmitter is a highperformance pressure transmitter with internationalleading technology meticulously designed by Pyrotechinstrument company,using the world's most advancedmonosilicon pressure sensor technology and patentencapsulation technology. Monosilicon pressure sensorlocates on the top of the metal body and stay away fromthe medium interface to realizes mechanical isolation andthermal isolation. Glass sintering sensor wire realizes highstrength electrical insulation of metal base and improvesthe capability of flexibility of electronic circuit and transientvoltage resistance protection. All these original encapsula--tion technologies enable PPTS to easily cope with extremechemical occasion and mechanical load, and own strongresistance to EMl, sufficient to respond to the rigorousindustrial environment applications, which are the genuineinvisible instruments.

Main parameters

Pressure types

Gauge pressure

Measuring range

2kPa-40MPa, please refer to theordering information chapter

Output signal

4-20mA,4-20mA+HART, customer

Reference accuracy

±0.1% URL, optional 0.075%URL

Field of application

Pressure, level

Measuring medium

Liquid, gas, or steam level, density and pressure

Approvals

Measuring range and limit

Nominal value

Smallest calibratable span

Lower range limit(LRL)

Upper range limit(URL)

Overload limit

40kPa

2kPa

-40kPa

40kPa

1MPa

250kPa

12.5kPa

-100kPa

250kPa

4MPa

1MPa

50kPa

-100kPa

1MPa

6MPa

3MPa

150kPa

-0.1kPa

3MPa

15MPa

10MPa

500kPa

-0.1kPa

10MPa

20MPa

40MPa

5kPa

-0.1kPa

40MPa

80MPa

Above measurement range can be replaced by kg/cm², MPa and kPa units .Which can provide other measurement range according to the requirements. Adjust requirements: lower range value (LRV) and upper range value (URV) can be adjusted within the scope of the upper and lower range limit, smallest calibratable span≤|URV-LRV| ≤ upper range limit

Standard specifications and reference conditions

Test standard: GB/T28474 / IEC60770; Zero based- calibration span, Silicon oil filling, 316L stainless steel isolated diaphragm, 4-20mA analog output.

Performance specifications

The overall performance including but not limited to 【reference accuracy 】,【environment temperature
effects】and other comprehensive error

Typical accuracy: ±0.1%URL

Stability: ±0.2% URL/ 5 years

Performance specifications

Standard and reference conditions, including linearity (BFSL), hysteresis and repeatability. calibration temperature: 20 ℃ ± 5 ℃

Linear output accuracy

TD≤10(Note1)

±0.1%URL

Nominal value: 40kPa,250kPa,1MPa,3MPa,10MPa,40MPa

10<TD<20

±0.01% URL

Note 1: TD is Turn down, TD=URL/ |URV-LRV|

Power supply effects

Zero and span change should not be more than ± 0.005% URL/V when power supply changes in 10.5/16.5-55VDC

Mounting position effects

Apply to any position. Max value lower than 400Pa can be corrected by zero clearing function.

Vibration effects

According to GB/T 1827.3/IEC61298-3 tests, <0.1% URL

Output signal

4-20mA two wire. Customers can choose linear output or square root output. Digital process variables superimpose on 4-20mA signal and apply to any hosts with HART protocol.

Ambient temperature effects(Typical)

➣ Within the range -20-80 ℃ total impact

➣ ±(0.1+0.15TD)% URL

Insulation resistance

≥20M Ω@, 100VDC

Damping time

Total damping time constant: equal to the sum of damping time of amplifer and sensor capsule

Damping time of amplifer: 0-100S adjustable

Diaphragm capsule (isolated diaphragm and silicon oil filling)
damping time: ≤0.2s

Startup after power off: ≤6S

Normal services after data recovery: ≤31S

Weight

Net weight: about 1.56kg ( without mounting bracket and process connection adaptor )

Environment condition

Items

Operational condition

Working
temperature

-40-85℃, integrated LCD display : -20-70℃

Storage temperature

-40-110℃, integrated LCD display: - 40-85℃

Media temperature

Silicon oil filling: -40-120℃

Working humidity

5-100% RH@40℃

Protection class

IP67

Dangerous condition

ExiaIICT4(GYB16.1962X) *
ExdIICT6(GYB16.1254X) *

* Only for 4-20mA output

Power supply

Item

Operating conditions

Standard/flame proof

10.5-55VDC

HART protocol

16.5-55VDC, communication load resistance 250Ω

Load resistance

0-2119 Ω for working condition, 250- 600Ω for HART protocol

Transmission distance

<1000m

Power consumption

≤500mW@24VDC, 20.8mA

Power supply and load requirements

EMC environment

NO.

Test items

Basic standards

Test conditions

Performance level

1

Radiated interference

GB/T 9254/CISPR22

30MHz-1000MHz

OK

2

Conducted interference (DC power port)

GB/T 9254/CISPR22

0.15MHz-30MHz

OK

3

Electrostatic discharge immunity test (ESD)

GB/T 17626.2/IEC61000-4-2

4kV(Contact ),8kV(Air)

B(Note2)

4

Immunity to radio frequency EM-fields

GB/T 17626.3/IEC61000-4-3

10V/m(80MHz-1GHz)

A(Note1)

5

Power frequency magnetic field Immunity
test

GB/T 17626.8/IEC61000-4-8

30A/m

A(Note1)

6

Electrical fast transient / Burst Immunity
Test

GB/T 17626.4/IEC61000-4-4

2kV(5/50ns,100kHz)

B(Note2)

7

Surge immunity requirements

GB/T 17626.5/IEC61000-4-5

1kV(Line to line) 2kV(Line to ground)
(1.2us/50us)

B(Note2)

8

Immunity to conducted disturbances
induced by radio frequency fields

GB/T 17626.6/IEC61000-4-6

3V(150kHz-80MHz)

A(Note1)

(Note 1)Performance level A: The preformance within the limits of normal technical specifications.
(Note 2)Performance level B: Temporary reduction or loss of functionality or preformance, it can restore itself. The actual
operating conditions, storage and data will not be changed.

Specific menu

Transmission module type

Output signal

Local control

PyroTech Instrument Pty Ltd
Head Office: 

Address: 7 Yamma Street Sefton NSW 2164, Sydney Australia.
Phone: 61 2 9721 8668 
Fax:   61 2 9738 9343
email: sales@pyrotech.com
Website: www.pyro-technology.com

China Office

Address: Room 401, Building 9, Jinbin Ruicheng, Jinbin Industrial Park, Wuqing District, Tianjin
Phone: ++86 15320153058
Fax:   ++86 022-88984836
Email: pyrotechcn@163.com
Website: www.pyro-technology.com

Username used for comment:
客户留言
Description:
验证码

Copyright PyroTech Instrument Pty Ltd. All Rights Reserved