ban12 ban12
ban01 ban01
ban02 ban02
ban03 ban03
ban04 ban04
ban05 ban05
ban06 ban06
ban07 ban07
ban09 ban09
ban08 ban08
ban11 ban11
ban10 ban10

SEARCH PRODUCTS

搜索
Search
Number of views:
673

PTT102

FEATURES / BENEFITS● RTD,TC, Ohm, or mV input● Extremely high measurement accuracy● HART 5 protocol● Galvanic isolation● For DIN form B sensor head mountingORDER YOUR TRANSMITTER: Use the part nu...
Number of views:
674
Product serial number
Quantity
-
+
Product description

FEATURES / BENEFITS

● RTD,TC, Ohm, or mV input

● Extremely high measurement accuracy

● HART 5 protocol

● Galvanic isolation

● For DIN form B sensor head mounting

ORDER YOUR TRANSMITTER: Use the part number: PTT-102

SPECIFICATIONS

Environmental Conditions

Operating Temperature

-40°C to +85°C

Calibration Temperature

20°C to 28°C

Relative humidity

< 95% RH (non-condensing)

Protection degree (enclosure/terminal)

IP68 / IP00

Mechanical Specifications

Dimensions

Ø 44 x 20.2 mm

Weight approx.

50 g

Wire size

1 x 1.5 mm2  / stranded wire

Screw terminal torque

0.4 Nm

Vibration

IEC 60068-2-6

2...25 Hz

±1.6 mm

25...100 Hz

±4 g

Common Specifications

Supply voltage

8...30 VDC

Isolation voltage, test / working

1.5 kVAC / 50 VAC

Response time (programmable)

1...60 s

Warm-up time

30 s

Programming

Loop Link & HART

Signal / noise ratio

Min. 60 dB

Accuracy

Better than 0.05% of selected range

Signal dynamics, input

22 bit

Signal dynamics, output

16 bit

Effect of supply voltage change

< 0.005% of span / VDC

EMC immunity influence

< ±0.1% of span

Extended EMC immunity: NAMUR NE21, A criterion, burst

< ±1% of span

Input Specifications

Max. offset

50% of selected max. value

RTD type

Pt100, Ni100, lin. R

Cable resistance per wire

5 Ω max. (up to 50 Ω per wire is possible with reduced measurement accuracy)

Sensor current

Nom. 0.2 mA

Effect of sensor cable resistance

< 0.002 Ω / Ω

Sensor error detection

Yes

TC input types

B, E, J, K, L, N, R, S, T, U, W3, W5

Cold junction compensation

< ±1.0°C

Sensor error current: when detecting / else

Nom. 33μA / 0 μA

Voltage input measurement range

-800...+800 mV

Min. measurement range (span)

2.5 mV

Input resistance

10 MΩ

Output Specifications

Signal range

4…20 mA

Min. signal range

16 mA

Load (@ current output)

≤ (Vsupply - 8) / 0.023 [Ω]

Load stability

≤ 0.01% of span / 100 Ω

Sensor error indication

Programmable 3.5…23 mA

NAMUR NE43 Upscale/ Downscale

23 mA / 3.5 mA

of span

= of the presently slected range

Observed Authority Requirements

EMC

2014/30/EU

EAC

TR-CU 020/2011

Approvals

ATEX 2014/34/EU

KEMA 03ATEX1537

IECEx

KEM 10.0083X

FM

FM17US0013X

CSA

1125003

INMETRO

DEKRA 18.0002X

EAC Ex TR-CU 012/2011

RU C-DK.GB08.V.00410

SIL

Hardware assessed for use in SIL applications

DNV-GL Marine

Stand. f. Certific. No. 2.4


We could not find any corresponding parameters, please add them to the properties table
Previous
Next

PyroTech Instrument Pty Ltd
Head Office: 

Address: 7 Yamma Street Sefton NSW 2164, Sydney Australia.
Phone: 61 2 9721 8668 
Fax:   61 2 9738 9343
email: sales@pyrotech.com
Website: www.pyro-technology.com

China Office

Address: Room 401, Building 9, Jinbin Ruicheng, Jinbin Industrial Park, Wuqing District, Tianjin
Phone: ++86 15320153058
Fax:   ++86 022-88984836
Email: pyrotechcn@163.com
Website: www.pyro-technology.com

Username used for comment:
客户留言
Description:
验证码

Copyright PyroTech Instrument Pty Ltd. All Rights Reserved