PTT105

FEATURES /BENEFITS● RTD or TC Input,Analog Output● High Definition Local Operator Interface (LOl) with 3 Optical Buttons● Selectable Red or White Backlight● Ex d Explosion Proof / Flame Proof Alum...
Number of views:
718
Product serial number
Quantity
-
+
Product description

FEATURES /BENEFITS

● RTD or TC Input,Analog Output

● High Definition Local Operator Interface (LOl) with 3 Optical Buttons

● Selectable Red or White Backlight

● Ex d Explosion Proof / Flame Proof Aluminum Head

● HART 7 Functionality with HART 5 Compatibility

HIGH DEFINITION DISPLAY

● 0,90,180,&270 degree position adjustments
● Monitoring, programming and diagnostics view
● Extensive diagnostics with flashing red or white backlight


LOCAL OPERATOR INTERFACE (LOI)

● 3 optical buttons; up, down and enter
● Dynamically adaptive to wear or accumulation of dirt
● lmmune to interference from ambient light sources
● Useable with or without gloves

CONFIGURATION

● From the LOl through guided menu
● PReset and HART modem
● HHC, DCS or AMS via HART


MOUNTING / INSTALLATION

● For installation in zone 0,1, 2 and zone 20,21, 22 and in Class 1,Division 1 and 2 applications
● Hardware assessed for use in SIL 2 applications
● Mounting on 1.5"-2" pipe bracket or on wall / bulkhead

APPLICATION

● Linearized temperature measurement with TC and RTD sensors e.g.Pt100 and Ni100
● HART communication and 4...20 mA analog PV output for individual,difference or average temperature measurement of up to two RTD orTC input sensors
● Up to 63 transmitters (HART 7) can be connected in a multidropcommunication setup


TECHNICAL CHARACTERISTICS

● NAMUR NE43 and NE89
● HART protocol revision can be changed by user configuration toeither HART 5 or HART 7 protocol

 

SPECIFICATIONS

Environmental Conditions

Operating Temperature

-40°C to +85°C

Storage Temperature

-40°C to +85°C

Calibration Temperature

20...28°C

Relative humidity

0...100% RH (condensing)

Protection degree

IP54 / IP66 / IP68 / type 4X

Mechanical Specifications

Dimensions

Ø 110 mm

Dimensions (HxWxD), aluminum

109.3 x 145 x 126 mm

Weight approx.

1.3kg

Wire size

0.13 x1.5 mm2  / AWG 26...16 stranded wire

Screw terminal torque

0.4 Nm

Vibration

IEC 60068-2-6

2...25 Hz

±1.6 g

25...100 Hz

±4 g

Number of digits

5

Backlight

Selectable ON/OFF

Backlight color

Selectable white or red

Common Specifications

Supply voltage, DC: Ex ia, intrinsically safe

10 (12 - with backlight)...30 VDC

Supply voltage, DC: Other

10 (12 - with backlight)...35 VDC

Isolation voltage, test / working

1.5 kVAC / 50 VAC

Response time
(programmable)

1...60 s

Signal / noise ratio

> 60 dB

Programming

HART

Start-up time, transmitter to display

Max. 5 s

Long-term stability, better than

±0.1% of span / year

Transmitter Accuracy

Better than 0.05% of selected range

Signal dynamics, input

22 bit

Signal dynamics, output.

16 bit

EMC immunity influence

< ±0.1% of span

Extended EMC immunity: NAMUR NE21, A criterion, burst

< ±1% of span

Max. offset.

50% of selected max. value

Input Specifications

RTD type

Pt50/100/200/500/1000; Ni50/100/120/1000

Cable resistance per wire

5 Ω (up to 50 Ω per wire is possible with reduced measurement accuracy)

Sensor current

Nom. 0.2 mA

Thermocouple type

B, E, J, K, N, R, S, T

Cold junction compensation (CJC)

Constant, internal or external via a Pt100 or Ni100 sensor

Output Specifications

Signal range

4…20 mA

Min. signal range

16 mA

Load (@ current output)

≤ (Vsupply - 10) / 0.023 [Ω]

Load resistance, with backlight

≤ (Vsupply - 12) / 0.023 [Ω]

Sensor error indication

Programmable 3.5…23 mA

NAMUR NE43 Upscale/ Downscale

23 mA / 3.5 mA

Updating time

440 ms

HART protocol revisions

HART 7 and HART 5

Observed Authority Requirements

EMC

2014/30/EU

EAC

TR-CU 020/2011

Approvals

EU RO Mutual Recognition Type Approval

MRA0000009

ATEX 2014/34/EU

DEKRA 15 ATEX 0058 X

IECEx

IECEx DEK 15.0039 X

FM

FM16US0009X / FM16CA0010X

CSA

70024231

EAC Ex TR-CU 012/2011

RU C-DK.GB08.V.01316

INMETRO

DEKRA 15.0014 X

NEPSI

GYJ15.1336X, GYJ15.1337X and GYJ15.1338X

SIL

Hardware assessed for use in SIL applications

We could not find any corresponding parameters, please add them to the properties table
Previous
Next

PyroTech Instrument Pty Ltd
Head Office: 

Address: 7 Yamma Street Sefton NSW 2164, Sydney Australia.
Phone: 61 2 9721 8668 
Fax:   61 2 9738 9343
email: sales@pyrotech.com
Website: www.pyro-technology.com

China Office

Address: Room 401, Building 9, Jinbin Ruicheng, Jinbin Industrial Park, Wuqing District, Tianjin
Phone: ++86 15320153058
Fax:   ++86 022-88984836
Email: pyrotechcn@163.com
Website: www.pyro-technology.com

Username used for comment:
客户留言
Description:
验证码

Copyright PyroTech Instrument Pty Ltd. All Rights Reserved